Search results for the GEO ID: GSE15902 |
(Click on the check boxes provided under "Select for analysis", to initiate grouping) |
(Once the selection is made, click on "Add groups" in "Make groups for comparison", to make a group. Scroll down) |
|
GSM ID | GPL ID |
Select for analysis |
Title |
Source name |
Description |
Characteristics |
GSM399126 | GPL1261 |
|
Whole Blood Chemical Hypoxic 1_8804
|
Whole Blood
|
stress: chemical hypoxia
|
Whole Blood was drawn from V. Cava.
|
Sample_geo_accession | GSM399126
| Sample_status | Public on Apr 25 2010
| Sample_submission_date | Apr 29 2009
| Sample_last_update_date | Nov 30 2009
| Sample_type | RNA
| Sample_channel_count | 1
| Sample_organism_ch1 | Mus musculus
| Sample_taxid_ch1 | 10090
| Sample_treatment_protocol_ch1 | At the beginning of the experiment mice were divided into two groups, control (room condition) and chemical hypoxic (room condition). For conditioning, the chemical hypoxic group was supplemented with 200ng of CoCl2 per 100ml/day. Animal’s weight and food intake were monitored daily. Food and water were changed daily during the course of the experiment. Before and after the experiments the hematocrit was monitored by taking blood from the tail vein of control and hypoxic animals. After 15 days animals were euthanized using CO2 after whole blood extraction from V. Cava for further analysis.
| Sample_molecule_ch1 | total RNA
| Sample_extract_protocol_ch1 | Total RNA was isolated and purified from 100ul of whole blood with the Mouse Ribopure-Blood RNA Isolation Kit (Ambion, Austin, Texas, USA) according to manufacturers instructions.
| Sample_label_ch1 | Biotin
| Sample_label_protocol_ch1 | Three microliter total RNA was used for each sample to obtain linearly amplified labeled cRNA by using GeneChip® One-Cycle Target Labeling kit (Affymetrix, Santa Clara, CA, USA) as described by manufacturer. Briefly, total RNA was used to generate double-stranded cDNA with the T7-oligo (dT) primer. This double-stranded cDNA was used in vitro transcription and biotin labeling steps. Labeled cRNA yield and purity were determined by measuring the absorbance at 260 and 280nm. All the cRNA 260/280 ratios were between 1.9 and 2.1. Quality control of the labeled cRNA products was assessed by performing 1µg labeled cRNA on 2% agarose gel to see similar RNA smear type.
| Sample_hyb_protocol | 15 micrograms of labeled cRNA from whole blood was fragmented, and 10ug was hybridized to Affymetrix Mouse 430 2.0 Gene Chip arrays for 18-24h (Affymetrix Inc.). Gene chip was washed and stained with streptavidin-phycoerythrin.
| Sample_scan_protocol | The chip was scanned at 6um resolution with Agilant model G2500A Gene Array scanner. A visual quality control measurement was performed to ensure proper hybridization after each chip was scanned.
| Sample_data_processing | Quality control parameters such as scaling factors used to normalize the chips, average background, and noise were also evaluated. In addition, raw intensities for each probe set were stored in electronic formats by the GeneChip operating system 1.1 (Affymetrix) for GC-RMA analysis in PARTEK software later on.
| Sample_platform_id | GPL1261
| Sample_contact_name | Gabriel,,Willmann
| Sample_contact_email | Gabriel.Willmann@med.uni-tuebingen.de
| Sample_contact_institute | University Eye Hospital and Centre for Ophthalmology Tübingen
| Sample_contact_address | Schleichstrasse 12-16
| Sample_contact_city | Tübingen
| Sample_contact_zip/postal_code | 72076
| Sample_contact_country | Germany
| Sample_supplementary_file | ftp://ftp.ncbi.nlm.nih.gov/geo/samples/GSM399nnn/GSM399126/suppl/GSM399126.CEL.gz
| Sample_series_id | GSE15902
| Sample_data_row_count | 45101
| |
|
GSM399127 | GPL1261 |
|
Whole Blood Chemical Hypoxic 2_8806
|
Whole Blood
|
stress: chemical hypoxia
|
Whole Blood was drawn from V. Cava.
|
Sample_geo_accession | GSM399127
| Sample_status | Public on Apr 25 2010
| Sample_submission_date | Apr 29 2009
| Sample_last_update_date | Nov 30 2009
| Sample_type | RNA
| Sample_channel_count | 1
| Sample_organism_ch1 | Mus musculus
| Sample_taxid_ch1 | 10090
| Sample_treatment_protocol_ch1 | At the beginning of the experiment mice were divided into two groups, control (room condition) and chemical hypoxic (room condition). For conditioning, the chemical hypoxic group was supplemented with 200ng of CoCl2 per 100ml/day. Animal’s weight and food intake were monitored daily. Food and water were changed daily during the course of the experiment. Before and after the experiments the hematocrit was monitored by taking blood from the tail vein of control and hypoxic animals. After 15 days animals were euthanized using CO2 after whole blood extraction from V. Cava for further analysis.
| Sample_molecule_ch1 | total RNA
| Sample_extract_protocol_ch1 | Total RNA was isolated and purified from 100ul of whole blood with the Mouse Ribopure-Blood RNA Isolation Kit (Ambion, Austin, Texas, USA) according to manufacturers instructions.
| Sample_label_ch1 | Biotin
| Sample_label_protocol_ch1 | Three microliter total RNA was used for each sample to obtain linearly amplified labeled cRNA by using GeneChip® One-Cycle Target Labeling kit (Affymetrix, Santa Clara, CA, USA) as described by manufacturer. Briefly, total RNA was used to generate double-stranded cDNA with the T7-oligo (dT) primer. This double-stranded cDNA was used in vitro transcription and biotin labeling steps. Labeled cRNA yield and purity were determined by measuring the absorbance at 260 and 280nm. All the cRNA 260/280 ratios were between 1.9 and 2.1. Quality control of the labeled cRNA products was assessed by performing 1µg labeled cRNA on 2% agarose gel to see similar RNA smear type.
| Sample_hyb_protocol | 15 micrograms of labeled cRNA from whole blood was fragmented, and 10ug was hybridized to Affymetrix Mouse 430 2.0 Gene Chip arrays for 18-24h (Affymetrix Inc.). Gene chip was washed and stained with streptavidin-phycoerythrin.
| Sample_scan_protocol | The chip was scanned at 6um resolution with Agilant model G2500A Gene Array scanner. A visual quality control measurement was performed to ensure proper hybridization after each chip was scanned.
| Sample_data_processing | Quality control parameters such as scaling factors used to normalize the chips, average background, and noise were also evaluated. In addition, raw intensities for each probe set were stored in electronic formats by the GeneChip operating system 1.1 (Affymetrix) for GC-RMA analysis in PARTEK software later on.
| Sample_platform_id | GPL1261
| Sample_contact_name | Gabriel,,Willmann
| Sample_contact_email | Gabriel.Willmann@med.uni-tuebingen.de
| Sample_contact_institute | University Eye Hospital and Centre for Ophthalmology Tübingen
| Sample_contact_address | Schleichstrasse 12-16
| Sample_contact_city | Tübingen
| Sample_contact_zip/postal_code | 72076
| Sample_contact_country | Germany
| Sample_supplementary_file | ftp://ftp.ncbi.nlm.nih.gov/geo/samples/GSM399nnn/GSM399127/suppl/GSM399127.CEL.gz
| Sample_series_id | GSE15902
| Sample_data_row_count | 45101
| |
|
GSM399128 | GPL1261 |
|
Whole Blood Chemical Hypoxic 3_8807
|
Whole Blood
|
stress: chemical hypoxia
|
Whole Blood was drawn from V. Cava.
|
Sample_geo_accession | GSM399128
| Sample_status | Public on Apr 25 2010
| Sample_submission_date | Apr 29 2009
| Sample_last_update_date | Nov 30 2009
| Sample_type | RNA
| Sample_channel_count | 1
| Sample_organism_ch1 | Mus musculus
| Sample_taxid_ch1 | 10090
| Sample_treatment_protocol_ch1 | At the beginning of the experiment mice were divided into two groups, control (room condition) and chemical hypoxic (room condition). For conditioning, the chemical hypoxic group was supplemented with 200ng of CoCl2 per 100ml/day. Animal’s weight and food intake were monitored daily. Food and water were changed daily during the course of the experiment. Before and after the experiments the hematocrit was monitored by taking blood from the tail vein of control and hypoxic animals. After 15 days animals were euthanized using CO2 after whole blood extraction from V. Cava for further analysis.
| Sample_molecule_ch1 | total RNA
| Sample_extract_protocol_ch1 | Total RNA was isolated and purified from 100ul of whole blood with the Mouse Ribopure-Blood RNA Isolation Kit (Ambion, Austin, Texas, USA) according to manufacturers instructions.
| Sample_label_ch1 | Biotin
| Sample_label_protocol_ch1 | Three microliter total RNA was used for each sample to obtain linearly amplified labeled cRNA by using GeneChip® One-Cycle Target Labeling kit (Affymetrix, Santa Clara, CA, USA) as described by manufacturer. Briefly, total RNA was used to generate double-stranded cDNA with the T7-oligo (dT) primer. This double-stranded cDNA was used in vitro transcription and biotin labeling steps. Labeled cRNA yield and purity were determined by measuring the absorbance at 260 and 280nm. All the cRNA 260/280 ratios were between 1.9 and 2.1. Quality control of the labeled cRNA products was assessed by performing 1µg labeled cRNA on 2% agarose gel to see similar RNA smear type.
| Sample_hyb_protocol | 15 micrograms of labeled cRNA from whole blood was fragmented, and 10ug was hybridized to Affymetrix Mouse 430 2.0 Gene Chip arrays for 18-24h (Affymetrix Inc.). Gene chip was washed and stained with streptavidin-phycoerythrin.
| Sample_scan_protocol | The chip was scanned at 6um resolution with Agilant model G2500A Gene Array scanner. A visual quality control measurement was performed to ensure proper hybridization after each chip was scanned.
| Sample_data_processing | Quality control parameters such as scaling factors used to normalize the chips, average background, and noise were also evaluated. In addition, raw intensities for each probe set were stored in electronic formats by the GeneChip operating system 1.1 (Affymetrix) for GC-RMA analysis in PARTEK software later on.
| Sample_platform_id | GPL1261
| Sample_contact_name | Gabriel,,Willmann
| Sample_contact_email | Gabriel.Willmann@med.uni-tuebingen.de
| Sample_contact_institute | University Eye Hospital and Centre for Ophthalmology Tübingen
| Sample_contact_address | Schleichstrasse 12-16
| Sample_contact_city | Tübingen
| Sample_contact_zip/postal_code | 72076
| Sample_contact_country | Germany
| Sample_supplementary_file | ftp://ftp.ncbi.nlm.nih.gov/geo/samples/GSM399nnn/GSM399128/suppl/GSM399128.CEL.gz
| Sample_series_id | GSE15902
| Sample_data_row_count | 45101
| |
|
GSM399129 | GPL1261 |
|
Whole Blood Chemical Hypoxic 4_8808
|
Whole Blood
|
stress: chemical hypoxia
|
Whole Blood was drawn from V. Cava.
|
Sample_geo_accession | GSM399129
| Sample_status | Public on Apr 25 2010
| Sample_submission_date | Apr 29 2009
| Sample_last_update_date | Nov 30 2009
| Sample_type | RNA
| Sample_channel_count | 1
| Sample_organism_ch1 | Mus musculus
| Sample_taxid_ch1 | 10090
| Sample_treatment_protocol_ch1 | At the beginning of the experiment mice were divided into two groups, control (room condition) and chemical hypoxic (room condition). For conditioning, the chemical hypoxic group was supplemented with 200ng of CoCl2 per 100ml/day. Animal’s weight and food intake were monitored daily. Food and water were changed daily during the course of the experiment. Before and after the experiments the hematocrit was monitored by taking blood from the tail vein of control and hypoxic animals. After 15 days animals were euthanized using CO2 after whole blood extraction from V. Cava for further analysis.
| Sample_molecule_ch1 | total RNA
| Sample_extract_protocol_ch1 | Total RNA was isolated and purified from 100ul of whole blood with the Mouse Ribopure-Blood RNA Isolation Kit (Ambion, Austin, Texas, USA) according to manufacturers instructions.
| Sample_label_ch1 | Biotin
| Sample_label_protocol_ch1 | Three microliter total RNA was used for each sample to obtain linearly amplified labeled cRNA by using GeneChip® One-Cycle Target Labeling kit (Affymetrix, Santa Clara, CA, USA) as described by manufacturer. Briefly, total RNA was used to generate double-stranded cDNA with the T7-oligo (dT) primer. This double-stranded cDNA was used in vitro transcription and biotin labeling steps. Labeled cRNA yield and purity were determined by measuring the absorbance at 260 and 280nm. All the cRNA 260/280 ratios were between 1.9 and 2.1. Quality control of the labeled cRNA products was assessed by performing 1µg labeled cRNA on 2% agarose gel to see similar RNA smear type.
| Sample_hyb_protocol | 15 micrograms of labeled cRNA from whole blood was fragmented, and 10ug was hybridized to Affymetrix Mouse 430 2.0 Gene Chip arrays for 18-24h (Affymetrix Inc.). Gene chip was washed and stained with streptavidin-phycoerythrin.
| Sample_scan_protocol | The chip was scanned at 6um resolution with Agilant model G2500A Gene Array scanner. A visual quality control measurement was performed to ensure proper hybridization after each chip was scanned.
| Sample_data_processing | Quality control parameters such as scaling factors used to normalize the chips, average background, and noise were also evaluated. In addition, raw intensities for each probe set were stored in electronic formats by the GeneChip operating system 1.1 (Affymetrix) for GC-RMA analysis in PARTEK software later on.
| Sample_platform_id | GPL1261
| Sample_contact_name | Gabriel,,Willmann
| Sample_contact_email | Gabriel.Willmann@med.uni-tuebingen.de
| Sample_contact_institute | University Eye Hospital and Centre for Ophthalmology Tübingen
| Sample_contact_address | Schleichstrasse 12-16
| Sample_contact_city | Tübingen
| Sample_contact_zip/postal_code | 72076
| Sample_contact_country | Germany
| Sample_supplementary_file | ftp://ftp.ncbi.nlm.nih.gov/geo/samples/GSM399nnn/GSM399129/suppl/GSM399129.CEL.gz
| Sample_series_id | GSE15902
| Sample_data_row_count | 45101
| |
|
GSM444068 | GPL1261 |
|
Whole Blood chamber Control 1 (5525)
|
Whole Blood
|
stress: control
|
Whole Blood was drawn from V. Cava.
|
Sample_geo_accession | GSM444068
| Sample_status | Public on Apr 25 2010
| Sample_submission_date | Aug 25 2009
| Sample_last_update_date | Nov 30 2009
| Sample_type | RNA
| Sample_channel_count | 1
| Sample_organism_ch1 | Mus musculus
| Sample_taxid_ch1 | 10090
| Sample_molecule_ch1 | total RNA
| Sample_extract_protocol_ch1 | Total RNA was isolated and purified from 100ul of whole blood with the Mouse Ribopure-Blood RNA Isolation Kit (Ambion, Austin, Texas, USA) according to manufacturers instructions.
| Sample_label_ch1 | Biotin
| Sample_label_protocol_ch1 | Three microliter total RNA was used for each sample to obtain linearly amplified labeled cRNA by using GeneChip® One-Cycle Target Labeling kit (Affymetrix, Santa Clara, CA, USA) as described by manufacturer. Briefly, total RNA was used to generate double-stranded cDNA with the T7-oligo (dT) primer. This double-stranded cDNA was used in vitro transcription and biotin labeling steps. Labeled cRNA yield and purity were determined by measuring the absorbance at 260 and 280nm. All the cRNA 260/280 ratios were between 1.9 and 2.1. Quality control of the labeled cRNA products was assessed by performing 1µg labeled cRNA on 2% agarose gel to see similar RNA smear type.
| Sample_hyb_protocol | 15 micrograms of labeled cRNA from whole blood was fragmented, and 10ug was hybridized to Affymetrix Mouse 430 2.0 Gene Chip arrays for 18-24h (Affymetrix Inc.). Gene chip was washed and stained with streptavidin-phycoerythrin.
| Sample_scan_protocol | The chip was scanned at 6um resolution with Agilant model G2500A Gene Array scanner. A visual quality control measurement was performed to ensure proper hybridization after each chip was scanned.
| Sample_data_processing | Quality control parameters such as scaling factors used to normalize the chips, average background, and noise were also evaluated. In addition, raw intensities for each probe set were stored in electronic formats by the GeneChip operating system 1.1 (Affymetrix) for GC-RMA analysis in PARTEK software later on.
| Sample_platform_id | GPL1261
| Sample_contact_name | Gabriel,,Willmann
| Sample_contact_email | Gabriel.Willmann@med.uni-tuebingen.de
| Sample_contact_institute | University Eye Hospital and Centre for Ophthalmology Tübingen
| Sample_contact_address | Schleichstrasse 12-16
| Sample_contact_city | Tübingen
| Sample_contact_zip/postal_code | 72076
| Sample_contact_country | Germany
| Sample_supplementary_file | ftp://ftp.ncbi.nlm.nih.gov/geo/samples/GSM444nnn/GSM444068/suppl/GSM444068.CEL.gz
| Sample_relation | Reanalysis of: GSM397842
| Sample_series_id | GSE15902
| Sample_data_row_count | 45101
| |
|
GSM444069 | GPL1261 |
|
Whole Blood Chamber Control 2 (5526)
|
Whole Blood
|
stress: control
|
Whole Blood was drawn from V. Cava.
|
Sample_geo_accession | GSM444069
| Sample_status | Public on Apr 25 2010
| Sample_submission_date | Aug 25 2009
| Sample_last_update_date | Nov 30 2009
| Sample_type | RNA
| Sample_channel_count | 1
| Sample_organism_ch1 | Mus musculus
| Sample_taxid_ch1 | 10090
| Sample_molecule_ch1 | total RNA
| Sample_extract_protocol_ch1 | Total RNA was isolated and purified from 100ul of whole blood with the Mouse Ribopure-Blood RNA Isolation Kit (Ambion, Austin, Texas, USA) according to manufacturers instructions.
| Sample_label_ch1 | Biotin
| Sample_label_protocol_ch1 | Three microliter total RNA was used for each sample to obtain linearly amplified labeled cRNA by using GeneChip® One-Cycle Target Labeling kit (Affymetrix, Santa Clara, CA, USA) as described by manufacturer. Briefly, total RNA was used to generate double-stranded cDNA with the T7-oligo (dT) primer. This double-stranded cDNA was used in vitro transcription and biotin labeling steps. Labeled cRNA yield and purity were determined by measuring the absorbance at 260 and 280nm. All the cRNA 260/280 ratios were between 1.9 and 2.1. Quality control of the labeled cRNA products was assessed by performing 1µg labeled cRNA on 2% agarose gel to see similar RNA smear type.
| Sample_hyb_protocol | 15 micrograms of labeled cRNA from whole blood was fragmented, and 10ug was hybridized to Affymetrix Mouse 430 2.0 Gene Chip arrays for 18-24h (Affymetrix Inc.). Gene chip was washed and stained with streptavidin-phycoerythrin.
| Sample_scan_protocol | The chip was scanned at 6um resolution with Agilant model G2500A Gene Array scanner. A visual quality control measurement was performed to ensure proper hybridization after each chip was scanned.
| Sample_data_processing | Quality control parameters such as scaling factors used to normalize the chips, average background, and noise were also evaluated. In addition, raw intensities for each probe set were stored in electronic formats by the GeneChip operating system 1.1 (Affymetrix) for GC-RMA analysis in PARTEK software later on.
| Sample_platform_id | GPL1261
| Sample_contact_name | Gabriel,,Willmann
| Sample_contact_email | Gabriel.Willmann@med.uni-tuebingen.de
| Sample_contact_institute | University Eye Hospital and Centre for Ophthalmology Tübingen
| Sample_contact_address | Schleichstrasse 12-16
| Sample_contact_city | Tübingen
| Sample_contact_zip/postal_code | 72076
| Sample_contact_country | Germany
| Sample_supplementary_file | ftp://ftp.ncbi.nlm.nih.gov/geo/samples/GSM444nnn/GSM444069/suppl/GSM444069.CEL.gz
| Sample_relation | Reanalysis of: GSM397843
| Sample_series_id | GSE15902
| Sample_data_row_count | 45101
| |
|
GSM444070 | GPL1261 |
|
Whole Blood Chamber Control 3 (5527)
|
Whole Blood
|
stress: control
|
Whole Blood was drawn from V. Cava.
|
Sample_geo_accession | GSM444070
| Sample_status | Public on Apr 25 2010
| Sample_submission_date | Aug 25 2009
| Sample_last_update_date | Nov 30 2009
| Sample_type | RNA
| Sample_channel_count | 1
| Sample_organism_ch1 | Mus musculus
| Sample_taxid_ch1 | 10090
| Sample_molecule_ch1 | total RNA
| Sample_extract_protocol_ch1 | Total RNA was isolated and purified from 100ul of whole blood with the Mouse Ribopure-Blood RNA Isolation Kit (Ambion, Austin, Texas, USA) according to manufacturers instructions.
| Sample_label_ch1 | Biotin
| Sample_label_protocol_ch1 | Three microliter total RNA was used for each sample to obtain linearly amplified labeled cRNA by using GeneChip® One-Cycle Target Labeling kit (Affymetrix, Santa Clara, CA, USA) as described by manufacturer. Briefly, total RNA was used to generate double-stranded cDNA with the T7-oligo (dT) primer. This double-stranded cDNA was used in vitro transcription and biotin labeling steps. Labeled cRNA yield and purity were determined by measuring the absorbance at 260 and 280nm. All the cRNA 260/280 ratios were between 1.9 and 2.1. Quality control of the labeled cRNA products was assessed by performing 1µg labeled cRNA on 2% agarose gel to see similar RNA smear type.
| Sample_hyb_protocol | 15 micrograms of labeled cRNA from whole blood was fragmented, and 10ug was hybridized to Affymetrix Mouse 430 2.0 Gene Chip arrays for 18-24h (Affymetrix Inc.). Gene chip was washed and stained with streptavidin-phycoerythrin.
| Sample_scan_protocol | The chip was scanned at 6um resolution with Agilant model G2500A Gene Array scanner. A visual quality control measurement was performed to ensure proper hybridization after each chip was scanned.
| Sample_data_processing | Quality control parameters such as scaling factors used to normalize the chips, average background, and noise were also evaluated. In addition, raw intensities for each probe set were stored in electronic formats by the GeneChip operating system 1.1 (Affymetrix) for GC-RMA analysis in PARTEK software later on.
| Sample_platform_id | GPL1261
| Sample_contact_name | Gabriel,,Willmann
| Sample_contact_email | Gabriel.Willmann@med.uni-tuebingen.de
| Sample_contact_institute | University Eye Hospital and Centre for Ophthalmology Tübingen
| Sample_contact_address | Schleichstrasse 12-16
| Sample_contact_city | Tübingen
| Sample_contact_zip/postal_code | 72076
| Sample_contact_country | Germany
| Sample_supplementary_file | ftp://ftp.ncbi.nlm.nih.gov/geo/samples/GSM444nnn/GSM444070/suppl/GSM444070.CEL.gz
| Sample_relation | Reanalysis of: GSM397844
| Sample_series_id | GSE15902
| Sample_data_row_count | 45101
| |
|
GSM444071 | GPL1261 |
|
Whole Blood Chamber Control 4 (5529)
|
Whole Blood
|
stress: control
|
Whole Blood was drawn from V. Cava.
|
Sample_geo_accession | GSM444071
| Sample_status | Public on Apr 25 2010
| Sample_submission_date | Aug 25 2009
| Sample_last_update_date | Nov 30 2009
| Sample_type | RNA
| Sample_channel_count | 1
| Sample_organism_ch1 | Mus musculus
| Sample_taxid_ch1 | 10090
| Sample_molecule_ch1 | total RNA
| Sample_extract_protocol_ch1 | Total RNA was isolated and purified from 100ul of whole blood with the Mouse Ribopure-Blood RNA Isolation Kit (Ambion, Austin, Texas, USA) according to manufacturers instructions.
| Sample_label_ch1 | Biotin
| Sample_label_protocol_ch1 | Three microliter total RNA was used for each sample to obtain linearly amplified labeled cRNA by using GeneChip® One-Cycle Target Labeling kit (Affymetrix, Santa Clara, CA, USA) as described by manufacturer. Briefly, total RNA was used to generate double-stranded cDNA with the T7-oligo (dT) primer. This double-stranded cDNA was used in vitro transcription and biotin labeling steps. Labeled cRNA yield and purity were determined by measuring the absorbance at 260 and 280nm. All the cRNA 260/280 ratios were between 1.9 and 2.1. Quality control of the labeled cRNA products was assessed by performing 1µg labeled cRNA on 2% agarose gel to see similar RNA smear type.
| Sample_hyb_protocol | 15 micrograms of labeled cRNA from whole blood was fragmented, and 10ug was hybridized to Affymetrix Mouse 430 2.0 Gene Chip arrays for 18-24h (Affymetrix Inc.). Gene chip was washed and stained with streptavidin-phycoerythrin.
| Sample_scan_protocol | The chip was scanned at 6um resolution with Agilant model G2500A Gene Array scanner. A visual quality control measurement was performed to ensure proper hybridization after each chip was scanned.
| Sample_data_processing | Quality control parameters such as scaling factors used to normalize the chips, average background, and noise were also evaluated. In addition, raw intensities for each probe set were stored in electronic formats by the GeneChip operating system 1.1 (Affymetrix) for GC-RMA analysis in PARTEK software later on.
| Sample_platform_id | GPL1261
| Sample_contact_name | Gabriel,,Willmann
| Sample_contact_email | Gabriel.Willmann@med.uni-tuebingen.de
| Sample_contact_institute | University Eye Hospital and Centre for Ophthalmology Tübingen
| Sample_contact_address | Schleichstrasse 12-16
| Sample_contact_city | Tübingen
| Sample_contact_zip/postal_code | 72076
| Sample_contact_country | Germany
| Sample_supplementary_file | ftp://ftp.ncbi.nlm.nih.gov/geo/samples/GSM444nnn/GSM444071/suppl/GSM444071.CEL.gz
| Sample_relation | Reanalysis of: GSM397845
| Sample_series_id | GSE15902
| Sample_data_row_count | 45101
| |
|
|
|
Make groups for comparisons |
(2 groups will be compared at a time) |
|
Select GSMs and click on "Add groups" |
Enter the group name here: |
|
|
|